The photoelectric signal is used to detect whether the object is toppled and output the high and low level signal control circuit. The photoelectric toppling switch is divided into two installation modes, vertical to the detected object and horizontal to the detected object.
Parameter | Symbol | Min | Typ | Max | Unit | Test Condition | |
Inp Emitter | Forward Voltage | VF | 1.2 | 1.3 | V | IF=20 mA | |
Reverse Current | IR | 10 | µA | VF=5V | |||
Peak Wavelength | lp | 940 | nm | ||||
Output Detector | Collector Dark Current | ICEO | 5 | 100 | nA | VCE=20V IF=0mA Ee=0mW/cm2 | |
Collector-Emitter Saturation Voltage | VCE(sat) | 0.1 | 0.4 | V | IC=0.25m AIF=20mA | ||
Upright Dump State Collector Current | IC(of) | 0.15 | mA | VCE=5V IF=20mA | |||
Dump State Collector Current | IC(on) | 0.5 | 5 | - | mA | VCE=5V IF=20mA | |
Transfer Characteristics | Rise Time | Tr | 15 | µS | Vcc=5V Ic=1mA RL=1000Ω | ||
Fall Time | Tf | 15 | MS |